5.2. Fault register

The Fault Register indicates the unit’s fault register. To read it, see the REG Command.

Bit(s)

Name

Fault Type

Description

[0]

Temperature Fault

Soft

Indicates a over-temperature fault or that the temperature sensor is disconnected

[1]

DC-Link Fault

Hard

DC-Link fault

[2]

Input OVC

Hard

Input Over-Current fault

[3]

Over-Power

Soft

Over-power fault

[4]

Earth-Leakage

Soft

Earth-Leakage fault - see Internal Memory id:115

[5]

Earth Fuse

Soft

Earth Fuse fault

[6]

Regulation Fault

Soft

Regulation fault - see Internal Memory id:120-122

[7]

Reserved

/

/

[8]

DCCT Error

Hard

DCCT Error

[9]

Reserved

/

/

[10]

Crowbar

Hard

Crowbar Fault

[11]

Quench

Soft

Quench Detection Fault - see Internal Memory id:130-134

[12]

Reserved

/

/

[13]

Output OVC

Hard

Output Over-Current Fault - Output current exceeded OVC Threshold (see Internal Memory id: 100)

[14]

Output OVV

Hard

Output Over-Voltage Fault - Output voltage exceeded OVV Threshold (see Internal Memory id: 101)

[15]

Reserved

/

/

[16]

External Interlock #1

Soft

External Interlock #1 Fault (see INTERLOCK Command)

[17]

External Interlock #2

Soft

External Interlock #2 Fault (see INTERLOCK Command)

[18]

External Interlock #3

Soft

External Interlock #3 Fault (see INTERLOCK Command)

[19]

External Interlock #4

Soft

External Interlock #4 Fault (see INTERLOCK Command)

[23:20]

Reserved

/

/

[24]

Parallel Config. Error

Soft

Model or Firmware mismatch between the Master and Slave unit(s)

[25]

Parallel Link Fault

Hard

Communication Error between the Master and Slave unit(s)

[26]

Reserved

/

/

[27]

Fan(s) Fault

Soft

Fan(s) Fault

[31:28]

Reserved

/

/

See also

  • For a detailed description of the faults, please refer to the User’s Manual