6.2. Fault Register
The Fault Register indicates the unit’s fault register. To read it, see the REG Command.
Bit(s) |
Name |
Fault Type |
Description |
---|---|---|---|
[0] |
Temperature Fault |
Soft |
Over-temperature fault - see Internal Memory id:110-111 |
[1] |
DC-Link Fault |
Hard |
DC-Link fault |
[2] |
Input OVC |
Hard |
Input Over-Current fault |
[3] |
Over-Power |
Soft |
Over-power fault |
[7:4] |
Reserved |
- |
- |
[8] |
DCCT Error |
Hard |
DCCT Error |
[9] |
Reserved |
- |
- |
[10] |
Output Relay Fault |
Hard |
Output Relay fault |
[12:11] |
Reserved |
- |
- |
[13] |
Output OVC |
Hard |
Output Over-Current Fault - see Internal Memory id: 100 |
[14] |
Output OVV |
Hard |
Output Over-Voltage Fault - see Internal Memory id: 101 |
[15] |
Reserved |
- |
- |
[16] |
External Interlock #1 |
Soft [1] |
External Interlock #1 Fault - see INTERLOCK Command |
[17] |
External Interlock #2 |
Soft [1] |
External Interlock #2 Fault - see INTERLOCK Command |
[18] |
External Interlock #3 |
Soft [1] |
External Interlock #3 Fault - see INTERLOCK Command |
[19] |
External Interlock #4 |
Soft [1] |
External Interlock #4 Fault - see INTERLOCK Command |
[25:20] |
Reserved |
- |
- |
[26] |
Thermocouple Fault |
Soft |
Thermocouple Fault - see Internal Memory id: 112-114 |
[27] |
Fan(s) Fault |
Soft |
Fan(s) Fault |
[31:28] |
Reserved |
- |
- |
See also
For a detailed description of the faults, please refer to the User’s Manual